Quick Summary
HTW-HT09B-3ANV1 is a Water and Boiler Heating Thermostat for water heating and boiler systems. It controls heating output using relay switching and dry contact. The unit supports NC, NO, and COM terminals for flexible connection. It works with 100–240Vac supply and provides stable temperature control.
This page explains how the Water and Boiler Heating Thermostat works in projects. It covers control logic, wiring method, and parameter setup. It also explains model configuration and customisation options. Typical questions and answers are included for quick reference.

Key Features
(This section explains the core control functions and their practical value.)
01 Dual Output Heating Control
The Water and Boiler Heating Thermostat supports 2x3A load outputs with NC, NO, and COM terminals. It also includes dry contact for boiler control. This allows flexible connection for different heating system layouts. Another model HTW-HT09B-3ANV3 can support Tuya WiFi function.
02 Stable Temperature Regulation
The thermostat uses sensor feedback to control heating output based on setpoint. It reduces temperature fluctuation during operation. This helps maintain stable room comfort and improves system reliability.
03 VA Screen Interface
The VA screen provides clear temperature display with black background. It improves visibility under different lighting conditions. This helps users read settings easily and reduces operation errors in daily use.
Product Design and Display
(This section shows the product’s dimensions and the interface layout.)

Technical Specifications
(This section lists the key parameters for reference and project confirmation.)
| Parameter | Value |
|---|---|
| Power Supply | 100~240Vac |
| Frequency | 50/60Hz |
| Accuracy | ±0.5°C |
| Sensor | NTC3950, 10K |
| Setpoint Range | 5~35°C |
| Display Range | 5~99°C |
| Material | PC + ABS (Fireproof) |
| Protection Class | IP20 |
Wiring Diagram
(This section provides the wiring reference diagram for correct installation.)

Model Code Guide
(This section explains what configuration the model code refers to.)
| Heating series | xx stands for |
| 3A | Water Heating, with NC+NO+COM output terminals |
| 16A | Electric Underfloor Heating, with L+N line voltage output terminals + External Sensor |
| NV | Boiler Heating, with Non-Voltage Dry Contact |
| 1 | 1 = Standalone |
| Example HTW-HT09B-xx: if xx = 3ANV1, it stands for water heating and boiler control with standalone function. Most sub-models are ready-made. Kindly contact us to confirm availability. | |
Project Fit & Customization
(This section explains where the product can be used, its limits, and OEM/ODM options.)
This Water and Boiler Heating Thermostat is not suitable for electric floor heating systems. It does not support fan coil control. It is not designed for WiFi or BMS communication. It is intended for basic heating control only.
Despite these limits mentioned above, ODM customisation can be discussed. Output configuration or control logic may be adjusted. Sensor settings or interface behaviour can also be adapted. Final feasibility depends on project requirements.
OEM services are available for branding and appearance changes. Logo printing, colour options, and label design can be supported. Packaging and interface adjustments may also be arranged for bulk orders.
Certificates and Compliance


Frequently Asked Questions
Q1. What systems does this Water and Boiler Heating Thermostat support?
This water and boiler heating thermostat supports water heating systems and boiler control using relay outputs and dry contact for flexible connection in different heating applications.
Q2. How is the thermostat wired in installation?
This water and boiler heating thermostat is wired to power supply and output terminals including NC, NO, COM, and dry contact for boiler connection based on system requirements.
Q3. Can it be used with electric floor heating systems?
No, this model is designed for water heating and boiler systems only and does not support electric floor heating control.
Q4. What is the MOQ and can I order samples?
We support sample orders. Standard MOQ is 300 units, but smaller trial quantities such as 100 units can also be discussed.
Q5. How can I place an order?
Please contact us to confirm requirements. We will provide a proforma invoice. Payment supports TT, PayPal, Visa, and terms like EXW, FOB, or DAP.
Q6. How will the products be shipped?
Courier delivery is recommended and takes about 7 days. Air shipping also takes around 7 days, while sea freight usually takes over one month.
Related Thermostat Models
If you are comparing models or selecting alternatives, please contact us. We can help match suitable thermostats based on your project needs.
Electric Underfloor Heating Thermostat
Water Underfloor Heating Thermostat
Final Note / Practical Takeaway:This Water and Boiler Heating Thermostat provides stable control for water and boiler systems. It supports flexible wiring and reliable operation in daily heating applications. 【More details: heating thermostat】