Quick Summary
The HTW-WF01-FC-2K is a thermostat with keycard designed for indoor fan coil unit systems in hotel and residential projects. It supports a 2-pipe system with heating and cooling control. The thermostat controls fan operation and motorised valves. It also supports keycard input for energy-saving control.
This thermostat with keycard is suitable for projects that need room energy management. It helps reduce energy use when rooms are empty. It also supports simple scheduling and practical daily operation. The sections below show key functions and main parameters clearly.

Key Features
These functions help the thermostat with keycard support stable room control and practical HVAC operation.
(01) White and black colour options
Two colour options are available to match different room styles. The clean appearance fits modern hotel rooms, apartments, and commercial interiors.
(02) 2-pipe heating and cooling system
The thermostat supports a 2-pipe on-off system. It controls heating and cooling through one water loop, making it suitable for standard FCU layouts. This thermostat with keycard is commonly used in hotel guest room projects.
(03) 3-speed fan
The unit controls fan coil operation. This helps manage heating and cooling output and keep the room temperature stable.
(04) Keycard function
The keycard input supports hotel energy-saving logic. When the card is removed, the system can stop or reduce operation to avoid energy waste in unoccupied rooms. This thermostat with keycard is suitable for energy-saving hotel applications.
Product Design and Display
The design is simple and clean. It fits indoor wall installation. The interface is easy to read. Buttons are clear and responsive. This thermostat with keycard is practical for daily use.


Technical Specifications
Key parameters are listed below for installation and system matching.
| Parameter | Value |
|---|---|
| Power Supply | 110–240VAC, 50/60Hz |
| Power Consumption | 5A |
| Set Range | 5–35°C |
| Accuracy | ±0.5°C or ±1°F |
| Installation | EU or Standard Electric Box |
| Protection Level | IP20 |
| Shell Material | PC+ABS (Fireproof) |
| Warranty | 2 Years |
Wiring Diagram
The wiring includes fan control, valve output, and keycard input. It supports energy saving logic. This thermostat with keycard is easy to install and connect.

Model Code Guide
This section explains what each part of the model code means for system configuration.
| Fan coil series | xx stands for |
| 2 | 2-pipe fan coil system |
| 4 | 4-pipe fan coil system |
| W | WiFi |
| EC | EC fan 0-10V |
| B | BACnet |
| N | Modbus communication |
| K | Keycard |
| E | External sensor |
| M | 0-10V modulating valve |
| Example WF01-FC-XX | If XX=4W, it means 4-pipe FCU thermostat with Wifi (If you need this, click here) |
Project Fit & Customisation
This section helps buyers confirm whether this thermostat with keycard fits the project scope before discussing ODM or OEM options.
This model is not suitable for projects that require built-in BMS communication, WiFi connection, App control, or remote cloud management as standard. It is also not the right choice for systems that need 4-pipe control, EC fan 0–10V output, external sensor logic, or advanced centralised control without further function changes.
Despite these limitations mentioned above, ODM function customisation can be discussed based on project needs and order quantity. For example, WiFi, Modbus, BACnet, external sensor support, 4-pipe control, or different control logic may be developed or adjusted on a suitable product platform.
OEM customisation is also available for brand and market needs. Options may include OEM logo printing, colour customisation, private label, packaging design, user manual adjustment, and model code labelling. These details can be discussed according to the target market, quantity, and project requirements.
Certifications and Compliance
The thermostat meets common HVAC standards. It supports safe and stable operation. This thermostat with keycard is suitable for long-term use.

Exhibition Moments
The product is shown in HVAC exhibitions. This helps improve design and application. This thermostat with keycard is already used in many projects.

Frequently Asked Questions
Q1: Is this model suitable for a 2-pipe fan coil system?
Yes. This model is designed for 2-pipe fan coil applications. It can control heating and cooling in one water loop, making it a practical choice for standard hotel room FCU projects.
Q2: Can this thermostat connect to BMS or central control systems?
This standard version is a standalone thermostat, so it does not include BMS communication by default. If your project needs Modbus, BACnet, or other communication functions, please feel free to get in touch with us to discuss a suitable customized version.
Q3: Does this model support external sensors?
The standard configuration does not include external sensor control. For projects that need remote temperature sensing, floor sensing, or special sensor logic, we can review the system requirements and check whether ODM function customization is suitable.
Q4: Can this model be customized for hotel projects?
Yes, project customization can be discussed. Depending on quantity and technical requirements, we can review options such as keycard logic, control settings, interface details, WiFi, communication protocol, or other suitable function adjustments. This thermostat with keycard can also be reviewed for different room management requirements.
Q5: What is the MOQ and can I get samples?
Yes, we support samples for testing. The usual MOQ is 300 units, but smaller trial orders, such as 100 units, can also be discussed for project evaluation.
Q6: How can I place an order and arrange shipping?
Please feel free to get in touch with us and share your project requirements first. After confirming the model, quantity, and delivery details, we will provide a PI. Payment can be arranged by TT, PayPal, Visa, and other agreed methods. Trade terms such as EXW, FOB, and DAP are available.
Q7: How long does it take to prepare the products?
Non-customized samples can usually be sent within 7 days. If customization is required, we need to evaluate the quantity, function changes, and software adjustment first. Custom projects usually take about 3–5 weeks. For a standard bulk order of around 300 units, preparation normally takes about one month.
Q8: What shipping methods are available?
For samples and small orders, we usually recommend door-to-door courier service such as FedEx, DHL, or UPS, which often takes about 7 days. Air freight may also take around 7 days, while sea shipping usually takes about one month or longer. The best option depends on order size, destination, and delivery schedule.
Need Support?
If you are selecting a model or planning a project, please contact us. We can help match the right thermostat.
Related Thermostat Models
More product details, please click directly:
Hotel HVAC systems need energy saving and stable control. This thermostat with keycard supports both needs in daily use. It helps reduce energy waste and improve system efficiency.