Quick Summary
HTW-WF11-FC-4K room thermostat is designed for hotel FCU systems. It controls a 3-speed fan and 4-pipe on/off valves, integrates keycard function, and operates in heating and cooling modes. Energy-saving mode supports efficient operation while maintaining guest comfort.
This page provides insights into control logic, key functional highlights, wiring diagrams, technical parameters, project fit and customization, and common project questions. Engineers and installers can quickly understand the operation and deployment of this room thermostat with keycard integration.
Key Functional Highlights
(This section explains the core control functions and their practical value.)
(01) 3-Speed Fan Control
The 3-speed fan adjusts airflow to match room temperature changes. It ensures quick response, improves comfort, and reduces energy consumption in hotel FCU systems.
(02) 4-Pipe On/Off Valve Control
This thermostat controls 4-pipe on/off valves precisely for both heating and cooling. Stable cycles avoid temperature overshoot and ensure reliable hotel room comfort.
For 2-pipe model with keycard feature, please refer to this model (HTW-WF11-FC-2K).
(03) Keycard Integration
Keycard disables HVAC when rooms are unoccupied. This prevents energy waste and aligns with hotel energy management strategies.
(04) Energy Saving Mode
Energy-saving mode optimises fan and valve operation based on occupancy and set-point. It balances comfort and efficiency, reducing operational costs.
Display
(This section shows the product’s dimensions and the interface layout.)


Specifications
(This section lists the key parameters for reference and project confirmation.)
| Parameter | Value |
|---|---|
| Power Supply | 95~240Vac, 50/60Hz |
| Current Load Fan Relay | 5A |
| Current Load Valve Relay | 5A |
| Built-in Sensor | NTC3950, 10K |
| Temperature Accuracy | ±0.5°C |
| Set-Point Range | 5~35°C |
| Warranty | 2 Year |
| Installation Box | EU round box or Standard 86x86mm Box |
Wiring
(This section provides the wiring reference diagram for correct installation.)

Guide
(This section explains what configuration the model code refers to.)
| Fan coil series | xx stands for |
|---|---|
| EC | EC fan |
| 2/4 | 2 for 2-pipe on/off; 4 for 4-pipe on/off system |
| M | Modulating valve control |
| W | Wi-Fi |
| N/B | N for Modbus; B for BACnet |
| K/E | K for Keycard; E for External sensor |
| Example HTW-WF11-FC-xx: if xx = 4K, it stands for a 3-speed fan, 4-pipe system with on/off valve control and keycard function. Most sub-models are ready-made. Kindly contact us to confirm availability. | |
Project Fit & Customization
(This section explains where the product can be used, its limits, and OEM/ODM options.)
HTW-WF11-FC-4K is designed for standalone hotel FCU applications. It is unsuitable for BMS integration requiring modulating valve control or high-humidity environments.
Despite these limits, ODM customization is supported. Firmware behaviour, keycard response, and energy-saving parameters can be tailored for specific projects. Discussion with our engineers ensures correct deployment.
OEM customization is available, including logo printing, colour adjustments, and labelling, making this room thermostat suitable for branded hotel deployments.
Certifications

Exhibition Moments

Frequently Asked Questions
1. Which FCU systems is HTW-WF11-FC-4K compatible with?
It is compatible with 4-pipe fan coil units with 3-speed fan and keycard function, commonly used in hotel rooms.
2. Can it manage heating and cooling efficiently?
Yes, it controls the fan and valve precisely to maintain stable room temperature in hotel environments.
3. How does the keycard function operate?
Keycard disables HVAC when rooms are unoccupied, preventing energy waste and improving efficiency for hotel operators.
4. What is the minimum order quantity and sample availability?
Samples are supported; standard MOQ is 300 units. Smaller batches can be discussed for pilot projects.
5. How to place an order?
Contact us. After confirming requirements, a proforma invoice is issued. Payment via TT, PayPal, or Visa. Terms EXW, FOB, DAP.
6. How is shipping handled?
Courier delivery usually takes 7 days. Air shipment 7 days; sea shipment one month plus, depending on location.
Need Support?
For project assistance, FCU thermostat selection, or keycard integration guidance, please contact us. Our team can advise on application planning and OEM customisation.